Testech Secumation Driver Download For Windows 10

Zoom into 2 Billion samples in just a blink of the eye. Each ScopeCorder is equipped with the revolutionary Giga Zoom Engine II, a powerful processor designed for optimizing access to data seamlessly. It is possible to activate 2 zoom windows while displaying the entire original signal. Scanner: Windows 7: Windows 8: Windows 10: Notes: 32 bit: 64 bit: 32 bit: 64 bit: 32 bit: 64 bit: 3M Cogent CSD 330 + (1) FIPS 201 PIV certified. Abilma UNITY: Scans palm prints, up to 4 flat fingerprints simultaneously or single rolled fingerprints. This download is licensed as freeware for the Windows (32-bit and 64-bit) operating system on a laptop or desktop PC from disk management without restrictions. Flash Drive Tester 1.14 is available to all software users as a free download for Windows.

PM052 - SMS/GPRS, Email Alert And Wireless Telemetry RTU

Specification: PM052D- 16 Digital Input (Dry Contact, DC to 50V Peak)
1 Pulse Counter Input (Rain Gauge)
4 Latch Relay Output (2.5A 24V Resetable Fuse Protected)
Expandable Digital/Analog IOs via RS485
PM052 - 8 Digital Input (Dry Contact, DC to 50V Peak)
8 x 16bit ADC (4-20mA) with digital calibration, 10hm
1 Pulse Counter Input (Rain Gauge)
4 Latch Relay Output 2.5A 24V Resetable Fuse Protected)
Expandable Digital/Analog IOs via RS485

Summary Of Features

End User Alert Mode: SMS
Automatic Regular Sending of Datalog via SMS: Yes
Support GPRS: Yes (static IP and dynamic IP)
Support ModBusTCP via GPRS: Yes

Power Supply: DC 7V to 35VDC, 1.2Watt nominal power consumption

LCD Display: BackLite 20 Character x 2 Line LCD
LCD Display GSM Network Signal Strength, System Date/Time, Status.

PC Interface: USB Virtual Serial for Setup and Console Interactive Status Display, Event Logging

LAN: 10BT Ethernet IP Web Server.(Optional)

RS232C: 1 x RS232C for interface to digital Temperature/RH Sensor

RS485: 1 x RS485 for expandable Digital IOs (up to 256 digital IOs) Support ModBus

4 x LATCHED Relay Output: Resettable Fuse Protected 2.5A, 24V Latching Relay can be map to any IOs (Digital, Analog, Pulse Input, Power) using Web Setup and Logical Expression to combine IOs to set or reset relay.

Non Volatile Logger Memory: Total of 4MByte onboard datalogger memory

Battery Backed Real Time Clock/Calender: Minimum 5 Years battery life.

Number Of Handphone and Emails: 8 Group of 10 Phone each, 80 Phone Number Maximum
GPS Modules: Optional 50 Channel superSensitivity (can use indoor)

SCADA HMI: TSCADA HMI for GPRS IP Remote Real Time Logging and Trending Display, as well as SMS Alert.

APPLICATION AREA

Computer Data Center: Monitoring Computer, UPS, PC Server, Water Leak, FM200, Temperature/Humidity.

SCADA System (Water Level, Flood Monitoring, Water Quality (PH, DO, Turbidity, Temp), VOC, TOC and other kind of Sensor Measurement

Weather Stations (Rain Gauge), Slope Movement.

Remote Event Alarm Notification. (UPS, Cold Room, Refrigeration, Electrical, Breaker, Solar Panel, Security Panel, Fire Alarm Panel, Lift Monitoring).

Remote System Reset via Wireless Means. The Relay output contact can be used to remotely reset your system or activate your remote system external trigger.

FLEXIBLE ASSIGNMENT OF IO TO GROUPS

Group of Phone/Email can be created such as each group can be enable/disable as well as assigned to specific IOs that will trigger the alert.

SMS Alert MONITORING MODE

PM052 support dual operating mode:

a) Direct SMS Message Send to User Handphone.
When Alarm Event occurs, Message are compose and then send directly to user handphone. The number of failed Send SMS can be set to automatically retry sending after a user specified interval. Each User can be alert via SMS . Each Person can be assign to Group, and each group can be assign to combination of inputs that will trigger an alert.

b) Server Mode: Send to Testech TSCADA HMI
When Alarm Event occurs, Message are compose and compressed and then send to Testech HMI Software running at the customer central monitoring PC equipped with a SMS/GPRS Modem and Broadband IP connection. Testech support BOTH Dynamic IP and Static IP.

This means that with our RTU you are assure of the best in both world of operating in standalone mode, Server Mode, and BOTH SIMULTANEOUS User+Server Mode by creating different Phone/IP group on the PM052.

The important implication is that our RTU is scalable, allowing customer to gradually scaled up the unit of deployment from standalone base to server base.

SMS QUERIES

User can send SMS (which has to be validated for a existing phone number in the PM052) can be send to querrie or activate the IO Control, as well as checking the system status including Telco signal strength, status of GPRS Connection, turn ON/ Turn off the relays etc.

GROUP CONFIGURATION AND ASSIGNMENT

Up to 8 Group of 10 Phone Each (that is total of 80 GSM Phone Number) can be setup on the RTU (via USB Serial or Keypad)

Group can be set to Server Mode (requires TSCADA Software) or User Mode (diret SMS Message Alert to user Mobile Phone)

Group can be Enable or Disable.

Devices

Inputs assignment can be assigned to each Group. For example if the RTU are connected to mechanical equipments, HVAC and electrical equipment etc and there are different team of maintenance responsible for each category of equipments, you can then alert ONLY the team that are responsible for the particular input that requires service attention when a alarm is send out via SMS

Each group and each individual phone can be individually enable and disable. Inputs can be assigned to different group.

PHONE CONFIGURATION AND ASSIGNMENT

Total of 80 GSM Phone number can be created in the PM052 RTU, by assigning up to 10 Phone Max to Each group (max 8 Groups).

Each Phone can be assign two different privilege mode

Supervisor Phone: Supervisor Phone can configure the unit and send control command to the unit (Turn Alarm ON/OFF, switch RTU to Online GPRS Mode, Switch RTU to OffLine SMS Mode, Turn Relay On, Change Phone Number, Enable/Disable Phone, Enable/DIsable Group)

User Phone: User Phone are only allow to receive alarm message via SMS or Poll the System (for example to check the input status again, or health check).

INPUT CONNECTORS.

Input Connector usng high quality 3mm connectors for fast removable screw connects. LED indication shows the status of the Latch Relay ON/OFF status.

DIGITAL INPUT CONFIGURATION AND ASSIGNMENT

Each Input can be individually setup to trigger SMS/EMAIL on Low, High, Alarm Limit Low or Alarm Limit High.

System and IO Status can be check by sending a SMS message to check RTU Health Status

System can be ARM, DISARM for maintenance.

Download

ANALOG INPUT CONFIGURATION AND ASSIGNMENT (PM051)

Each Analog Input resolutions is 16bit instrumentation grade Aanalog To Dgiital Converter accepts directly 4-20mA Input.

Each Analog Input can trigger an alert due to High Limit, Low Limits or both.

Hysterysis allows user to change the band of changes that that it allows allowance as the alarm cross the boundary of each Alarm Limits to capture for Analog sensor that hover around the limits.

Analog Alarm can be assign to individual group.

Testech Secumation Driver Download For Windows 10 32-bit

Each Channel can be individually configure for zero and span, engineering scaling.

Engineering Scaling: The Low Reading and Full Scale Reading can be scaled to user Engieering Units up to 4 digitals + 1 decimal Place (-9.999 to +999.9)

Low Alarm and Hysterisis: Low Alarm can be set with hysterisis (that is if input falls below the Low Alarm trip point), SMS wll be send and the Alarm will only be clear if input reovers to Low Alarm trip point + hysterisis.

High Alarm and Hysterisis: High Alarm can be set with hysterisis (that is if input rises above the High Alarm trip point), SMS wll be send and the Alarm will only be clear if input reovers to Low Alarm trip point + hysterisis.

ANALOG ADC CALIBRATION

The ADC can be calibrated by the user by using a Process calibrator. Each ADC has 5 points digital calibration for the best linearity. During calibration, the value read in are compare against against accept value.

PM052 uses FULL Digital calibration and there is no TrimPot or Potentiometer. Thefore the long term stability of ADC reading is very good.

RELAY OUTPUT

PM052 has 4 Relay Output able to handle up to 2.5A current @ 24V. Each Relay Output are protected by resettable fuse that will not require user to replace fuse. This relay can be user for example interface to external Light Pole, Siren, Reset External Equipment etc. Optionally Input can be assign to relay to activate the relay for example to activate siren or light pole.

The Relay are Latching Type (it will retain its ON/OFF condition even when power off)

These Relays are easily Map to Digital, Analog, Power, EdgeDetect, IP Ping Results using the websetup and user can program the logical expresssion to turn on/off the Specific Relays (for example IF D1 OR D2 OR A1 is ALARM condition THEN turn Relay#1 ON).

Likewise relayout Output can be manually Turn ON/Off by user via Web interface or SMS, for example to turn on machines, aircon, lights etc.

USB Interface

Console interface using any Serial Terminal Software such as Windows HyperTerminal for interactive login, system setup, maintenance check, and configure of Input Description, Alarm Trigger, Group, Phone Number.

Changes made can be save into PM05x interval Non Volatile Memory to permanently store the setup.

EVENT LOGGING

All Event (System Login, System Reset, IO Event, Send SMS Operations etc) are logged and save in battery backup memory. By Default, up to 100 event are invidually time stamed and store in the event log in the internal non volatile Flash Memories, and using the addtional built in 32MByte Non Volatile Flash Memories, unlimited event log is possible.

RS232C And RS485

The PM052 has a External RS232C to allow interface to external peripheral and equipment such as datalogger, please talk to us for any custom interfacing including RS232C/RS485. For example we can interface to GPS/Datalogger/Swipe Card Reader etc.

INTERFACE TO TEMPERATURE AND HUMIDITY SENSOR

Testech Secumation Driver Download For Windows 10 Kms

The PM052 directly interface to a digital temperature/RH Thermohygrometer. No analog channel is required.

Temperature: -20 to +85°C +/- 0.5°C, 0.0625°C resolution.
Humidity: 0 - 100% RH +/- 0.6%RH, 0.04% RH resolution
Built in Hydrophobic Filter Protects Sensor Against Dust, Dirt, Moisture, and Contaminants
Sensor are individually calibrated in a NIST-Traceable Chamber

MicroSD Interface

Optionally MicroSD Interface allows removable datalog storage media in order to upload data to PC. Support FAT16 up to 2GB MicroSD Media

EXPANDABLE IOs

Additional IO can be expanded and connect to the PM05x to support up to 16 external IO Modules (that is up to 16 x 16 digital inputs = 256 digital inputs). Digital INput are optoisolated. Combination of Opto Isolated Digital In, Digiout Out, Analog Input are supported.

OPTIONAL SCADA (WINDOWS/WEBSERVER/IP CAMERA)

The WebBase or Windows Base developed by Testech Electronics has allows many units of PM052 to be monitor from one central server using enterprise level SQL server. User Phones/Email are store on the Server, and the unit monitor and logs all the RTU on 24/7 basis.

Specific sustom HMI has been developed for Data Monitoring, Water Qualities, Flood level Monitoring, Turbdity sensors, Volatile Organic Compound, Weather Stations etc. Each parameter of the SCADA IOs can be modify to suit user sensors.

Windows

Testech Secumation Driver Download For Windows 10

SCADA support DVR and IP Camera for real time streaming videos integrated into the SCADA remote Monitoring.

Contact us for free consultation for your custom projects.

Link to TSCADA Download USB Driver for PM05x

Testech Secumation Driver Download For Windows 10 64-bit

Back to M2M Main Page | Back to Testech Home Page | Water/Weather Instrumentations